The Mastervolt AC Master power inverter produces a pure sine wave AC (Alternating Current) output from a DC (Direct Current) input from your boats battery bank. Because of the pure sine wave output, it is safe and reliable and prevents damage to the equipment it is connected to. The inverter is easy to install and features built in protection against over-temperature, overload, short circuit, high or low battery voltage and reverse polarity.
The power inverter is robustly built and delivers the full output even in demanding conditions. The high frequency technology used eliminates noise typically associated with power inverters, such as buzzing or humming. It also features an automatic power saving mode, meaning a longer run time and less strain on your batteries. The 28212500 model is MasterBus compatible and can be used with remote control M70405080 for easy operation.
With the 2500 Watt model, you can use a 3 phase system, or combine up to 15 units in parallel for higher power outputs.
General specifications
Output voltage: 230/240 V - 50/60 Hz (selectable)
Output waveform: true sine
Nominal battery voltage: 12 V
Recommended battery capacity: ≥ 270 Ah
Continuous power at 25 °C / 77 °F, cos phi 1: 2500 W
Continuous power at 40 °C / 104 °F, cos phi 1: 2500 W
Peak load (3 s): < 3000 W
Peak load (< 0.2 s): < 4000 W
AC connection: hardwired with UK plug
Galvanisedanic isolation: yes
Efficiency: 88 %
Parallel configuration: yes, up to 15 units
3-Phase configuration: yes, 3 units
Display/read-out: LED indication: battery voltage, load level, status
Alarms: potential free alarm contact
Dimensions, hxwxd: 283 x 436 x 128mm (11.1 x 17.2 x 5.0 inch)
Weight: 8 kg (17.6 lb)
Compliance: CE, E-mark, RCM
Technical specifications
Technology: high frequency, input & output fully isolated
Low battery voltage, switches off at: 10.5 V
Low battery voltage, switches on at: 12.5 V
High battery voltage, switches off at: 16.5 V
High battery voltage, switches on at: 14.5 V
Input current (nominal load): 250 A
No-load power consumption (ON mode): < 3.6 A
No-load power consumption (energy saving mode): < 1.1 A
Minimal DC fuse (slow blow): 300 A
Minimal cable size: 95mm²
Harmonic distortion typical: < 5 %
Cos phi: all power factors allowed
Transfer system: integrated, automatic (inverter to grid: 8~10 ms, grid to inverter: 16~50 ms). Not for parallel & 3-phase operation (external transfer system possible)
Temperature range (ambient temp.): -20 °C to 60 °C, derating power > 40 °C (-4 °F to 140 °F)
Cooling: temperature and load controlled fan
Protection degree: IP21, horizontal wall mounting
Protections: over-temperature, overload, short circuit, high/low voltage, reverse polarity (fuse)
MasterBus compatible: yes, using a MasterBus AC Master Interface