Branch circuit breakers (also used for 24-hour circuit protection)
Compact design enables high density circuit protection configurations
Push-to-reset operation
Trip Free design cannot be held ON during fault current condition
Optional push button waterproof boot protects circuit breaker in wet environments
Specification:
Interrupting Capacity: 3,000A @ 14.7V DC, 2,500A @ 28V DC
Voltage Max Operating: 32V DC
Temp Operating: Min: -10°C, Max: 60°C
Type: Thermal trip, manual reset
Terminals: 1/4" Male Quick Connect
Mounting: 3/8" - 27 UNS
Mount Screw Torque: 6-8 in-lb Recommended
Regulatory: CE marked. UL Recognized - UL 1077-UL/cUL (USA and Canada), TUV certified. Meets UL 1500 and ISO 8846 external ignition protection requirements.