Automatically shares single source of charge with Auxiliary Battery
120A continuous rating to support high output alternators
12V/24V DC auto ranging voltage input
Senses charging on two battery banks
Side and bottom knockouts for cable connections
Clip-on cover insulates terminal connections
Studs accept multiple cable terminals
One-piece stainless flange nuts ensure safe and secure connections
Integrated LED indicates ACR status
Quick connect terminals for ground and optional features
Optional Features
Optional Auxiliary Battery Priority connection shares the alternator charge with
the Auxiliary battery longer when the engine is running to allow the use of auxiliary
loads for an extended period of time
Remote LED remotely indicates ACR states - requires optional LED
Specifications
Intermittent Rating: 5 min. 210A
Continuous Rating 120A
(Combine) Amperage Operating Current 175mA
(Open) Amperage Operating Current 15mA
Nominal Voltage 12V / 24V DC
Cable Size to Meet Ratings 1 AWG (50mm²)
Maximum Cable Size 1/0 AWG (50mm²)
Terminal Stud Size 3 /8"-16 (M10)
Maximum Battery Size 850 CCA
Relay Contact Position 12V DC 24V DC
Combine (30 sec.) 13.6V DC 27.2V DC
(2 min.) 13.0V DC 26.0V DC
Open Low (30 sec.) 12.75V DC 25.5V DC
Over Voltage Lockout 16.0V DC --
Open Low (30 sec.) 12.25V DC 24.5V DC